Troubleshooting / Component Workarounds |
This topic contains troubleshooting tips for the Imaging Worker.
Some requests that require the Imaging Worker might remain in pending for a long time. For example: an import task or a paravirtual instance run. If request remains in pending, the Imaging Worker instance might not able to run because of a lack of resources (for example, instance slots or IP addresses).
You can check for this scenario by listing latest AutoScaling activities:
euscale-describe-scaling-activities -g asg-euca-internal-imaging-worker-01
Check for failures that indicate inadequate resources such as:
ACTIVITY 1950c4e5-0db9-4b80-ad3b-5c7c59d9c82e 2014-08-12T21:05:32.699Z asg-euca-internal-imaging-worker-01 Failed Not enough resources available: addresses; please stop or terminate unwanted instances or release unassociated elastic IPs and try again, or run with private addressing only